Polyimide Tape Technical Data Sheet

图片1polyimide-tape-test-sample-preparation
图片1polyimide-tape-test-sample-preparation

The Polyimide Tape Technical Data Sheet compares published silicone, acrylic and ESD-grade values for thickness, peel adhesion, tensile behavior, electrical breakdown and heat exposure. These construction-specific figures are references, not common acceptance limits. Steel adhesion cannot predict removal from every coating; a reflow peak cannot establish continuous service temperature. Confirm edge retention, adhesive traces and electrical suitability on representative samples under actual heating, cooling and handling conditions.

Film Gauge Is Not Finished Thickness

A published silicone grade has 25 um backing and 60-66 um finished thickness. The polyimide tape range includes different adhesive systems. The following table separates grade-specific data.

Grade-Tagged Published Properties

Item

Reference Value

Test / Condition

Notes

Silicone film / total

25 / 60-66 um

Published silicone grade

Liner excluded

Acrylic total thickness

50-80 um

Published acrylic grades

Acrylic only

Steel peel, silicone / acrylic

2.3 N/cm / 2.5-4.0 N/25 mm

Methods incomplete

Not comparable

Tensile, silicone / acrylic

45 N/cm / >=115 N/25 mm

Published grades

Widths differ

Elongation, silicone / acrylic

35% / >=40%

Published grades

Unconfirmed method

Electrical breakdown

6.5-7.5 / >=6.0 kV

Silicone / acrylic

Not operating voltage

Service / brief heat

180 / 260 C silicone; 150 / 180 C acrylic

Published grades

Time-specific

Reflow observation

10 cycles; 245-250 C peak

Silicone trial on FR4

Not continuous

ESD resistance / unwind

10^6-10^9 ohm/sq / <50 V

Special ESD grade

Separate measurements

Reproducible Measurements

Test

Checks

Method / Reference

Reason

Request When

Thickness

Film vs total

ASTM D3652

Avoid stack-up error

Approval

180-degree peel

Removal force

ASTM D3330; speed, dwell

Steel differs from FR4

Masking

Tensile / elongation

Rupture / stretch

ASTM D3759

Tearing

Slit strips

Breakdown / heat / ESD

Failure / charge

ASTM D1000; heat cycle; ESD method

Separate mechanisms

Relevant grades

Qualification on Actual Substrates

On FR4 or coated metal, record pressure, dwell and cooling. After heating, inspect edge lift, bubbles, shadow, tearing and residue. Use 24 h / 72 h / 7 day peels when relevant.

Failure Signals Before Approval

Data

Too Low

Too High

Failure Risk

Verification

Peel

Edge lift

Removal difficult

Leakage / transfer

Aged substrate peel

Thickness

Below design

Fit interference

Clearance mismatch

Film / total gauge

Heat / ESD

Outside range

Beyond validation

Residue / static

Cycle / charge tests

Lot and Storage Evidence

Record lot, settings, storage age, moisture, sunlight and transport exposure. Set acceptance limits.

FAQ

Why does finished tape exceed PI film thickness?

Adhesive adds thickness; exclude liners.

Can steel peel predict FR4 removal?

No. Test solder mask and dwell.

Is 260 C a continuous rating?

No. Verify duration, cycles and removal.

Does ESD resistance predict unwind voltage?

No. Test resistance and charge separately.