Mylar Aluminum Foil Tape








- Construction: Solid aluminum foil laminated to PET/Mylar.
- Available structures: AL/PET; AL/PET/AL where offered.
- Appearance: Metallic silver foil; PET finish by grade.
- Thickness: Foil, PET and total laminate specified separately.
- Adhesive: External PSA and release liner only when specified.
- Formats: Slit roll, pad or spool to agreed dimensions.
Mylar aluminum foil tape combines a distinct aluminum foil layer with PET (Mylar) film through a lamination bond. The foil forms the metallic shielding layer, while PET supports handling, cable wrapping and dielectric separation where the construction allows. Used in cable shielding and industrial converting, the laminate must be specified by its individual layer gauges, wrapping conditions and roll dimensions.
Composite Construction
AL/PET has one solid aluminum foil layer bonded to PET; AL/PET/AL places PET between two foil layers. PET/AL/PET has PET outer faces, while metallized PET uses deposited aluminum rather than a separate foil gauge. These constructions are not interchangeable. The aluminum tape construction range provides the broader comparison; cable laminates should still be specified by layer sequence rather than treated as ordinary sealing tape.
Aluminum polyester Mylar tape uses solid foil as the metallic layer and PET as mechanical support. Foil thickness affects metallic coverage; PET thickness affects handling, flexibility and cable fit. The internal lamination bond joins foil to PET and is not an external pressure-sensitive adhesive (PSA); specify any external PSA and release liner separately. In markets using British spelling, the product may also be listed as mylar aluminium foil tape.
AOBERIS TAPE should confirm the actual layer sequence and individual gauges by grade.

Benefits
- Separate foil and PET gauges for clearer material control.
- PET support for slitting, winding and cable wrapping.
- Foil/PET face arrangement to suit the cable design.
- Slit rolls, pads or spools matched to converting equipment.
How Should Aluminum Foil and PET Thickness Be Balanced in a Cable Laminate?
Aluminum gauge contributes to the metallic screen; PET gauge affects support, flexibility and cable fit. Thicker PET may be too stiff on small diameters. Trial the laminate at the intended line speed and tension.
Published supplier examples include AL9/PET12 at 24 um total and AL9/PET23 at 35 um. These are market references, not AOBERIS TAPE test results. Total thickness includes the bonding layer, so specify foil, PET and finished thickness separately, with tolerances.

Cable Applications
- Pair shielding in communication and data cables that specify a foil/PET wrapping structure.
- LAN, network and coaxial cable assemblies using laminated shielding components.
- Signal, control and instrumentation cables requiring defined layer thickness and dielectric separation.
- Industrial cable converting with slit rolls, narrow-width rolls or spools.
Technical Data and Converting References
| Parameter | AL9/PET12 | AL9/PET23 | AL9/PET15/AL9 | Converting reference |
|---|---|---|---|---|
| Aluminum foil thickness | 9 um | 9 um | 9 um per side | – |
| PET film thickness | 12 um | 23 um | 15 um | – |
| Total laminate thickness | 24 um | 35 um | 39 um | – |
| Basis weight | 44.0 g/m2 | 59.3 g/m2 | Not published | – |
| Tensile strength | 90 MPa | 110 MPa | Not published | – |
| Elongation at break | 30% | 30% | Not published | – |
| Dielectric / shielding | Not published | Not published | Not published | Test required |
| Slit width | – | – | – | PAD: 5-1000 mm; spool: 3.5-80 mm |
| Width tolerance | – | – | – | Supplier example: +/-0.1 mm |
| Core ID / maximum OD | – | – | – | PAD: 76/102/152 mm, OD 80-600 mm; spool: 76 mm, OD 300-320 mm |
| Roll length / format | – | – | – | Length by order; slit roll, pad or spool |
ASTM D882 covers thin-film tensile testing; ASTM D149 covers dielectric breakdown. ASTM D4935 is for planar shielding, while IEC 62153-4-3 addresses cable-shield transfer impedance. State the specimen, method and conditions with every result.
Which Cable Wrapping and Roll Specifications Should Be Confirmed Before Slitting?
Match cable diameter, tape width, wrapping method, pitch and overlap. Longitudinal and spiral wrapping create different coverage. Too little overlap can leave gaps; too much adds material and finished diameter. Some cable specifications call for at least 25% overlap, while guidance for certain FTP/STP designs gives 20%-30%. Treat these as references and verify the required coverage on the actual cable.
Before slitting, agree width tolerance, length, core ID, maximum OD, winding direction and splice policy. Trial for wrinkles, stretching, foil-edge cracks, pinholes, delamination and telescoping. Confirm steady payoff at line speed and tension. Aluminum polyester tape for cable shielding must match the cable drawing and converting process.
FAQ
Does Mylar aluminum foil tape include a pressure-sensitive adhesive?
Not always. The internal bond joins foil to PET; external PSA and release liner depend on the specified grade.
How should AL/PET and AL/PET/AL be selected?
Choose by cable design, foil coverage, flexibility and wrapping process. Confirm availability by grade.
How is the required wrapping overlap determined?
Use cable diameter, tape width, pitch and wrapping method, then verify coverage in a production trial.
What should be checked during incoming inspection?
Check layer sequence, foil and PET gauges, total thickness, bond condition, slit width, edge quality, winding, core ID and OD against the approved specification.