Foil Scrim Kraft Tape

Fibreglass Grid Aluminium Foil Tape Roll
Reflective Fiberglass Foil Tape Roll
Reflective Fiberglass Foil Tape Rolls
Fibreglass Grid Aluminium Foil Tape Roll
Reflective Fiberglass Foil Tape Roll
Reflective Fiberglass Foil Tape Rolls
  • Construction: Aluminum foil + fiberglass scrim + kraft paper
  • Scrim: 2-way / 3-way, grade dependent
  • Color: Silver
  • Adhesive: Pressure-sensitive, grade dependent
  • Liner: Paper release liner, grade dependent
  • Format: Jumbo rolls / slit rolls

Foil scrim kraft tape combines aluminum foil, fiberglass scrim and kraft paper in a pressure-sensitive laminate for compatible FSK-faced insulation joints. Unlike plain foil or foil-scrim tape without kraft, it is used on duct wrap, duct board seams and vapor-retarder joints. Selection depends on scrim, adhesive, temperature and roll specifications. The complete laminate should match the facing and installation conditions.

FSK Backing Construction and Layer Functions

Foil forms the facing, fiberglass scrim resists handling tension and tearing, and kraft paper supports the composite. Lamination adhesive bonds these permanent layers; pressure-sensitive adhesive attaches the tape to the insulation. Kraft is permanent backing, not the removable liner. Compare foil-scrim reinforced tape without a specified kraft layer when the job needs reinforcement but does not call for the complete FSK laminate. When a joint requires fiberglass reinforcement without the permanent Kraft backing used in FSK tape, reinforced aluminum foil tape is a separate laminate construction to evaluate. Compare the two against the specified facing, adhesive contact conditions, and installation stress before selecting either grade.

One published facing reference lists 7.6 um foil, 49 g/m2 kraft and tri-directional scrim with 2 yarns/in MD and 3 yarns/in XD. These are facing values, not finished-tape specifications.

Tape TypeBackingDifference
Plain foilFoilNo scrim or kraft
Foil-scrimFoil + scrimKraft must be verified
FSKFoil + scrim + kraftComplete laminate

Adhesive Performance and Facing Compatibility

Acrylic and synthetic-rubber adhesives suit different bonding conditions. Compare tack, peel and holding power by grade. For fsk aluminum foil tape, test the actual FSK facing: a steel-panel result does not establish adhesion to a coated foil-and-kraft surface.

Published examples report 18.3 N/25mm on one tape and 7 N/10mm on stainless steel for another. Different test bases prevent direct comparison. Record substrate, dwell time and temperature.

Benefits

  • Complete FSK backing for compatible insulation joints.
  • Fiberglass reinforcement assessed through tensile and tear testing.
  • Adhesive grades matched to the facing and bonding conditions.
  • Helps maintain facing continuity when correctly applied.

Which Conditions Should Be Checked Before Sealing an FSK-Faced Insulation Joint?

Keep the facing clean, dry and free of dust, oil or loose coating. Cover the seam without stretching the tape and press evenly, especially at the edges. On below-ambient ductwork, inspect overlaps and penetrations for gaps in vapor-retarder continuity. Check adhesion on the actual facing after the specified dwell. Tape does not replace separate fitting seals.

Technical Data Sheet

ParameterMarket ReferenceAOBERIS TAPE
Foil thickness7.6 um, facingPending
Kraft basis weight49 g/m2, facingPending
Scrim3-way; 2 MD / 3 XD yarns per inchConfirm grade
Backing thickness0.10 mm, tapePending
Total thickness, no liner0.14 / 0.19 mm, separate tapesPending
Total thickness, with liner0.28 mm, one tapePending
Peel to steel18.3 N/25mm, one tapePending
Peel to stainless steel7 N/10mm, another tapePending
Peel to FSKActual facing test requiredPending
Tensile strength173.5 N/25mm or 59.5 N/10mmPending
Elongation2% / 3%, separate tapesPending
Tear resistanceTest method requiredPending
Application temperatureGrade dependentPending
Service temperature-40 to 116 C / -29 to 127 CPending
Roll width / length48 / 72 / 96 mm x 46 m, one referenceConfirm
Core ID3 inch, one referenceConfirm

State whether thickness includes the liner. Application temperature is for installation; service temperature applies after bonding. Peel reports need substrate and dwell time; tensile reports need MD/XD direction. Relevant methods include ASTM D3652, D3330 and D3759.

Applications

  • FSK-faced fiberglass duct-wrap seams.
  • Fiberglass duct-board joints and facing closures, where approved.
  • Vapor-retarder seams and overlaps.
  • HVAC insulation joints and compatible FSK repairs.

UK specifications may call this foil scrim kraft tape; confirm that kraft is permanently laminated, not a removable liner.

Roll Formats and Manufacturing Quality

Specify width, length, core ID, diameter and tolerance. One market example lists 48, 72 and 96 mm widths, 46 m length and a 3-inch core; these are not confirmed AOBERIS TAPE sizes.

Inspect lamination, scrim alignment, adhesive coating, backing thickness, slit width and winding. AOBERIS TAPE specifications should identify the approved backing, adhesive, liner and dimensions, supported by batch records. UL 723 / ASTM E84 claims require product-specific reports; ASTM C1136 concerns insulation facings and UL 181A specified duct closure systems. FSK construction alone proves neither compliance.

How Should 2-Way and 3-Way Fiberglass Scrim Be Specified?

2-way scrim reinforces machine and cross directions; 3-way adds a diagonal direction. Compare yarn count, mesh spacing and MD/XD tensile and tear data. The 2 MD / 3 XD yarns-per-inch example is not universal. Three-way is not automatically stronger; yarn size and lamination matter.

FAQ

How is FSK tape different from plain foil tape?

It has permanent foil, fiberglass scrim and kraft backing; plain foil tape does not.

Will it adhere to every FSK facing?

No. Compatibility depends on the facing, coating and adhesive grade. Test the actual surface.

Is 3-way scrim always stronger than 2-way?

No. Compare yarn construction, directional tensile strength and tear results.

Does FSK construction guarantee UL 181A or UL 723 compliance?

No. Require documentation for the exact product and tested configuration.

Scroll to Top

Get A Free Quote Now !

Contact Form Demo (#3)