Glass Cloth Insulation Tape










AOBERIS TAPES manufactures Glass Cloth Insulation Tape for motor, transformer, coil, lead-wire, and cable-insulation work where woven fiberglass backing is selected for mechanical reinforcement together with electrical insulation requirements. Select the supplied grade against the intended insulation position, adhesive system, and approved electrical data.
- Backing: woven fiberglass cloth
- Adhesive: silicone, acrylic, or thermosetting rubber
- Color: white standard, other colors by request
- Thickness: 0.13 mm – 0.25 mm, grade dependent
- Width: 5 mm – 200 mm slit rolls available
- Length: 30 m, 33 m, 50 m, or specified length
Product Overview
Glass Cloth Insulation Tape is selected where electrical insulation points also need a woven backing that resists tearing, abrasion, and dimensional movement during wrapping. Typical positions include motor lead anchoring, end-turn wrapping, transformer outer and layer insulation, crossover protection, coil banding support, and reinforced cable sections. The final insulation system depends on the complete assembly, so selection should be based on the actual adhesive grade, electrical test data, thermal-ageing requirement, overlap design, varnish or resin contact, and approved sample.
Adhesive choice changes the working boundary of the tape. Silicone, acrylic, and thermosetting rubber systems can behave differently in heat ageing, bonding, converting, varnish exposure, and removal, so only values verified for the supplied grade should be used. For application examples and failure questions, see What Is Glass Cloth Electrical Tape Used For?.

Benefits
- Supports motor, transformer, coil, lead-wire, and cable-insulation positions when the selected grade is approved for the electrical system.
- Woven fiberglass backing provides mechanical reinforcement during tight wrapping and handling.
- Grade-specific adhesive systems allow electrical, thermal-ageing, varnish, and bonding requirements to be evaluated separately.
- Tight overlap, slit-edge quality, and dimensional stability can be checked on the real winding geometry before approval.
- Flame-retardant or other certified performance should be claimed only for the exact grade and test method supported by documentation.
- Heat-aged adhesion, flagging, lifting, and insulation gaps should be evaluated during representative sample testing.

What Should Be Confirmed Before Glass Cloth Insulation Tape Is Used on Transformer Coils?
Before this tape is approved for transformer coil wrapping, thickness and width are only part of the selection. The actual insulation position should be reviewed first: outer coil wrap, layer support, crossover insulation, lead pad hold-down, or end-turn fixing. Each position may need a different balance of tensile strength, conformability, dielectric breakdown value, flame-retardant behavior, and heat-aging stability. For dry transformer work, sample rolls should be tested with the actual winding shape, varnish or resin process, lead wire movement, and expected operating temperature. This helps confirm whether the tape keeps adhesion, resists edge tearing, and avoids lifting after winding pressure and heat exposure.

TDS
| Item | Typical Value |
|---|---|
| Product Type | Glass cloth electrical insulation tape |
| Backing Material | Woven fiberglass cloth |
| Adhesive System | Silicone adhesive, acrylic adhesive, or thermosetting rubber adhesive |
| Total Thickness | 0.13 mm – 0.25 mm, selected by insulation grade |
| Standard Color | White, other colors by production agreement |
| Slit Width Range | 5 mm – 200 mm, custom slitting available |
| Roll Length | 30 m, 33 m, 50 m, or specified length |
| Temperature Rating | Grade specific; confirm approved TDS, adhesive system, test method, and exposure condition |
| Dielectric Breakdown Reference | Grade specific; confirm breakdown-voltage test method and approved product data |
| Insulation Resistance | Checked after normal condition or heat aging, grade dependent |
Applications
- Motor insulation for lead wires, end turns, winding sections, and heat-exposed electrical joints.
- Transformer insulation for coil outer wrapping, layer support, crossover insulation, and lead fixing.
- High voltage cable wrapping where dielectric strength, tight overlap, and edge stability are important.
- Coil banding and anchoring in equipment exposed to vibration or thermal cycling.
- Wire harness insulation where ordinary plastic tape may soften, shrink, or tear.
- Repair and reinforcement of electrical insulation systems after sample validation.
How Should Glass Cloth Insulation Tape Be Matched to Motor Leads and High Voltage Cable Wrapping?
For motor leads and high voltage cable wrapping, this tape should be selected by both electrical stress and mechanical stress. The woven fiberglass backing adds tear resistance, abrasion support, and heat stability, while the adhesive controls how well the tape stays in place after thermal cycling. Silicone adhesive is usually preferred for hotter zones. Rubber or acrylic systems may be selected when bonding behavior, handling, or cost balance is more important. During approval, check dielectric strength, adhesion after heat aging, flame-retardant grade, wrapping overlap, cable bend radius, and slit-edge cleanliness during tight spiral wrapping.
FAQ
Is glass cloth insulation tape the same as ordinary electrical tape?
No. Ordinary electrical tape is usually PVC based. Glass cloth insulation tape uses woven fiberglass backing, so it gives better heat resistance, tear resistance, and mechanical support for motors, transformers, coils, and cables.
Which adhesive should be selected for high temperature electrical insulation?
Silicone adhesive is often selected for higher-temperature motor and transformer insulation. Acrylic or thermosetting rubber adhesive can be used when different adhesion, handling, or cost balance is required.
Can this tape support flame retardant electrical assemblies?
Only when the exact supplied grade has supporting flame-performance documentation and the complete insulation system is validated by the required test method. The fiberglass backing alone does not establish a flame-retardant rating for the finished assembly.
What should be tested before bulk production?
Before bulk production, test thickness, width tolerance, dielectric breakdown, insulation resistance, adhesion after heat aging, tensile strength, flame retardant behavior, coil winding tension, cable bend radius, overlap wrapping, and retained sample consistency.