Butyl Tape Data Sheet: Peel Adhesion, Shear & Temperature Test Data




This butyl tape data sheet compares peel, shear, creep and temperature data for unsupported, reinforced and foil-faced butyl seals. Force readings depend on specimen geometry, substrate, conditioning and failure mode. The published figures represent independent grades, not this site’s verified specifications. Confirm the actual joint with representative specimens. Report the substrate finish, preparation, load and environmental exposure, because nominal readings alone cannot determine suitability.
The Specimen Must Be Defined Before the Force
Unsupported butyl can stretch or split; reinforcement redistributes force. Record thickness, backing, liner removal and clamping.
Match the specimen structure against the butyl sealant tape range before comparing figures.
Record failure locus.
Peel Strip, Loaded Lap or Compressed Seal?
Test Item | What It Checks | Suggested Method or Reference | Why It Matters | When To Request It |
Peel adhesion | Interface separation | ASTM D3330 if applicable; H41 internal | Geometry sensitivity | New substrate |
Dynamic shear | Rapid shear | H15 internal | Not creep | Grade changes |
Static holding | Slow slip | ASTM D3654 if applicable | Load duration | Loaded joints |
Sealant tensile | Bond/cohesive failure | ASTM C907 if applicable | Failure locus | Compressed joints |
Membrane T-peel | Film separation | H45; 250 um membrane | Steel differs | Membrane changes |
For peel, record substrate, width, speed, dwell and failure locus; internal H-methods are not ASTM equivalents.

Published Numbers Kept With Their Original Grades
Item | Typical Value / Reference Range | Test Method or Condition | Notes |
Total thickness | 1.0 mm [E, F] | Published grades | Grade-specific |
180-degree peel | 8 [A], 11 [B], 14 [C] N/cm | Internal H41 | Match dwell |
180-degree peel to stainless steel | 60 [E1], 50 [E2] N/25mm | JIS Z 0237:2000, as cited | Different structures |
90-degree peel | 7 [A], 11 [B], 7 [C] N/cm | Internal H48 | Angle-dependent |
Dynamic shear | 12 [A-C], 13 [D] N/cm2 | Internal H15 | Not holding time |
Membrane T-peel | 12 N/cm [D] | H45; 250 um membrane | Film-dependent |
Tensile elongation | 200% [E1], 9% [E2] | JIS Z 0237:2000, as cited | Different structures |
Service temperature | -20 to +60 C [B]; -40 to +90 C [A, D]; -40 to +110 C [C] | Published grade ratings | Not installation range |
A Strong Peel Can Still Conceal Slow Joint Movement
Peel is not a seal test; rapid shear cannot predict creep. Service-temperature ratings exclude installation limits and outdoor life.

Steel-panel results may differ from membrane bonding. Test double-sided butyl vapor barrier tape on the actual film.

Record film treatment, pressure and dwell against a control.
A Membrane Coupon Needs Its Own Observation Record
At 24 h, 72 h and 7 days, inspect compression and spread as optional checkpoints.
Inspect edge lift, migration, squeeze-out, bubbles, shadows and tears; record fracture location.

For alternate joint geometries, see industrial uses for butyl tape; verify the assembly separately.
Specify leak-test criteria.
Where a Number Can Mislead the Joint Decision
Data Point | If Too Low | If Too High | Risk in Application | Check Before Full Use |
Thickness (E/F: 1.0 mm) | Gap underfill | Extrusion | Voids | Joint compression |
Peel (A-C: 8/11/14 N/cm) | Edge release | Coating disturbance | Interface mismatch | Matched peel test |
Dynamic shear (A-D: 12/13 N/cm2) | Weak rapid-load resistance | Creep unproven | Creep risk | Static-load trial |
Elongation (E1/E2: 200%/9%) | Limited movement | Construction-dependent | Backing damage | Confirm construction |
Service limit (B/C: +60/+110 C) | Poor heat margin | Life unproven | Flow | Aging test |
Preserve Exposure History Alongside the Result
Record grade, lot, liner, storage and compression history.
Compare exposed rolls with controls; record fixture and operator.
FAQ
How should I compare peel figures in a butyl tape data sheet?
Match angle, surface, speed and dwell; units alone are insufficient.
Will a high peel force confirm a watertight compressed joint?
No. Test the compressed joint for leakage and movement.
What should a creep record capture that dynamic shear misses?
Log load, area, temperature, duration, slip and censored results.
When should a stored or transported roll be retested?
Compare suspect rolls with retained controls.